Back to Top

Hi, Guest!
  • PORTABLE FLUE GAS ANALYZER FOR OXYGEN, CARBON MONOXIDE, CARBON DIOXIDE, & OXIDES OF NITROGEN, Model : 376 SERIES, Brand : Nova

PORTABLE FLUE GAS ANALYZER FOR OXYGEN, CARBON MONOXIDE, CARBON DIOXIDE, & OXIDES OF NITROGEN, Model : 376 SERIES, Brand : Nova

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
35 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail PORTABLE FLUE GAS ANALYZER FOR OXYGEN, CARBON MONOXIDE, CARBON DIOXIDE, & OXIDES OF NITROGEN, Model : 376 SERIES, Brand : Nova

The Nova 376 Series Portable Analyzers provide a detailed analysis of flue gas composition. They have been designed for accuracy, reliability, and ease of use and service. The sensors respond quickly to the gases of interest present in the flue gas sample. Under normal conditions of use, the O2, CO and NOx sensors each have a life expectancy of between 3 and 4 years and are customer-replaceable. The CO2 sensor should not need to be replaced. Specifications Method of Detection Customer replaceable electrochemical O2, CO and NO sensors Solid state infra-red detector for CO2 Ranges Available 0-20.0% CO2 0-200 to 0-2000 PPM NOx ( as NO) ranges available 0-2000 PPM and 0-4.00% CO - Switch selectable 0-25.0% O2 Resolution 0.1% O2 and CO2, 1 PPM CO and NOx Accuracy & Repeatability Within ± 0.1% O2 and CO2; ± 10 PPM CO and NO Drift 2% full scale per 8 hours of continuous operation Response Time ( T-90) 10-15 seconds for O2; 20-30 seconds for CO, NO, and CO2 Ambient Temperature Range 0 to 40º C, 32 to 105º F Linearity ± 1.0% of full scale for each gas measured Size & Weight 16" L x 4 1/ 2" H x 8" D @ 13 lbs ( 40.6 x 20.3 x 10.8 cm @ 5.6 kg) Power AC/ DC Operation, 115 VAC 60 Hz for recharging ( Other voltages available.) Output Options 4-20 mA or 0-1 VDC Hazardous Area Rating Options General Purpose, Non-Hazardous Applications Analysis of oxygen ( O2) , carbon monoxide ( CO) , carbon dioxide ( CO2) and oxides of nitrogen ( NOx as NO) in flue gas from furnaces, heaters, and boilers. May be used on commercial, industrial and residential combustion equipment. Features Rugged design that is easy to operate and maintain Fast warm up and response CO2 actually measured by infra-red detector, not calculated Dual CO range : 0-2000 ppm & 0-4.00% Rapid reading recovery after CO or NO ' overdose' Digital readout meters with backlight Rechargeable battery operation Built in sample pump, filter and flow meter Active condensate removal Weatherproof ( WP) cabinet with clear Lexan cover Stainless steel probe with sample hose Use on any fuel Options Outputs of 0-1 V or 4-20 mA ( can be isolated) Special sampling probes Suitcase ( K) style cabinet available AC power only operation Gas alarms with LED Detachable/ portable data logger Calibration Air for O2 span and CO/ CO2 zero Analyzed gas mixtures of CO2, CO, and NOx in nitrogen for span
Tampilkan Lebih Banyak