Back to Top

Hi, Guest!
  • Process Analyzer for Oxygen by Paramagnetic Sensor, Model : 412 Series, Brand : Nova

Process Analyzer for Oxygen by Paramagnetic Sensor, Model : 412 Series, Brand : Nova

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
16 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Process Analyzer For Oxygen By Paramagnetic Sensor, Model : 412 Series, Brand : Nova

The Nova 412 Series O2 analyzers utilize a magneto-dynamic paramagnetic measuring cell and powerful selenium cobalt magnet assembly with on-board pre-amplification to provide the highest standard of O2 analysis. Accuracy is further augmented by built-in barometric pressure compensation and detector temperature control. For high purity applications ( Model 412HP) , a high resolution digital readout is added. Specifications Method of Detection Magneto-dynamic paramagnetic O2 cell Ranges Available 412 - any range from 0-2.0% to 0-100.0% O2; 412HP - 98.0 to 100.0 or 0 to 100.00 O2 Resolution 412 - 0.1% O2; 412HP - 0.01% O2 Accuracy & Repeatability ± 0.5% of full scale or 0.05% , whichever is greater Drift ± 0.2% of full scale per month Response Time ( T-90) 4-5 seconds Ambient Temperature Range 32 to 122° F ( 0 to 50° C) @ 5-95% RH non-condensing. Lower temperatures ( -5° F, -20° C) with Cold Weather Package. Sample dew point should be at least 9° F ( 5° C) below lowest sample temperature. Linearity ± 0.5% of full scale or 0.05% , whichever is greater Size & Weight Dimensions will vary depending on enclosure style and options required Power 115 VAC, 60 Hz - 220 VAC, 50 Hz Output Options 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs Alarms High and/ or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Analyzer Type O2 Analyzer Hazardous Area Rating Options General Purpose, Non-Hazardous Applications For continuous analysis of oxygen ( O2) in process gas streams that contain gases that interfere with other methods of O2 measurement. For high accuracy or high purity applications. Features Highest accuracy O2 analyzer, very stable Fast response ( T90 - 4 to 5 seconds) and bright digital readout Linear over entire 0-100% range Microprocessor control for push button calibration Non-consumable O2 detector, no periodic replacement required Built in sample pump or pressure regulator, and 4 - 20 mA outputs To improve accuracy, detector is mounted in temperature controlled heated box and compensated for changes in barometric pressure at the vent Options Hi/ Low gas, low flow, and diagnostic alarms available Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available Sample conditioning systems available for removal of moisture, acidic gas, and dust Cabinet purge system available for use in hazardous areas One-step ' cal-now' button with touch screen LCD display Full automatic calibration with touch screen LCD display Cold weather package for operation to -20° C ( -4° F) Cabinet coolers can be fitted to most models High purity version available for 98-100% O2 ( 412HP) Calibration Nitrogen for zero Air or analyzed calibration gas for span
Tampilkan Lebih Banyak