Detail CONTINUOUS PROCESS ANALYZER FOR HYDROGEN AND DEW POINT, Model : MODEL 430DPL, Brand : Nova
The Nova 430DPL analyzer utilizes a temperature-controlled T/ C cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as a recorder output. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement.
For dew point, the 430DPL has a capacitive ceramic sensor. The output of this sensor is directly proportional to the dew point of the sample gas. After the sample gas has been analyzed for H2 and dew point, both signals are amplified and displayed on digital meters and are provided as voltage or current outputs for recording.
Specifications
Method of Detection
Temp-controlled T/ C cell for H2; capacitive ceramic sensor for dew point
Ranges Available 0-2, 0-5, 0-10, 0-20, 0-50, and 0-100% H2
-148 to 68° F ( -100 to 20° C) Dew Point
Resolution ± 0.1% H2, ± 1° dew point
Accuracy & Repeatability ± 1% of full scale
Drift Zero and Span ± 1% of full scale per week
Response Time ( T-90) 10-15 seconds to 90% step change
Ambient Temperature Range
32 to 122° F ( 0 to 49° C) . lower temperatures ( -5° F, -20° C) with cold weather package
Linearity 1% of full scale
Size & Weight Dimensions will vary depending on enclosure style and options required
Power 115 VAC, 60 Hz - 220 VAC, 50 Hz
Output Options 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
Alarms High and/ or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating
Analyzer Type H2 Analyzer
Hazardous Area Rating Options
General Purpose, Non-Hazardous
Applications
For continuous analysis of up to 100% hydrogen ( H2) and low range dew point in process gas streams such as heat treating, hydrogen/ nitrogen atmospheres and H2 cooled generators.
Features
Best value continuous H2 and dew point analyzer
Bright digital readout
Fast response ( T90-10-15 seconds)
Easy to operate
Long life thermal conductivity ( T/ C) H2 detector with high accuracy and repeatability.
Cannot be burned out due to loss of flow
Long life ceramic dew point sensor
Low range of -148 to 68° F ( -100 to 20° C) dew point
Built in sample pump or pressure regulator
Modular layout that is easy to maintain
Options
Hi/ Low gas, low flow, and diagnostic alarms available
Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
Sample conditioning systems available for removal of acidic gas and dust
Cabinet purge system available for use in hazardous areas
One-step ' cal-now' button with touch screen LCD display
Full automatic calibration with touch screen LCD display
Cold weather package for operation to -5° F ( -20° C)
Cabinet coolers can be fitted to most models
High temperature filters and probes
Calibration
Nitrogen for zero
Analyzed calibration gas for H2 and known ambient dew point for dew point span.