  • pH - Conductivity Dissolved Oxygen - Temperature, Model : HD 98569, Brand : DeltaOhm

pH - Conductivity Dissolved Oxygen - Temperature, Model : HD 98569, Brand : DeltaOhm

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
41 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail PH - Conductivity Dissolved Oxygen - Temperature, Model : HD 98569, Brand : DeltaOhm

The HD 98569 is a portable multi-parameter data logger for electrochemical measures: pH, conductivity, dissolved oxygen and temperature. It is fitted with a large back-lighted LCD display. The instrument measures: • pH, mV, redox potential ( ORP) with pH, redox or combined pH/ temperature electrodes complete with SICRAM module; • conductivity, resistivity in liquids, total dissolved solids ( TDS) , and salinity with combined 4-ring and 2-ring conductivity and temperature probes with SICRAM module. • Concentration of dissolved oxygen in liquids ( in mg/ l) , saturation index ( in % ) using SICRAM combined probes of polarographic type with two or three electrodes and integrated temperature sensor. The instrument ifs fitted with input for the measurement of temperature with Pt100 immersion, penetration or contact probes with SICRAM module. • The pH electrode calibration can be carried out on one or five points and the calibration sequence can be chosen from a list of 8 buffers. Temperature compensation can be automatic or manual. • The conductivity probe calibration can be performed with automatically detected conductivity calibration solutions: 147¼ S/ cm, 1413¼ S/ cm, 12880¼ S/ cm, 111800¼ S/ cm or manually with calibration solutions having different values. • The dissolved oxygen probe’ s quick calibration function guarantees longterm correctness of the performed measurements. • pH, conductivity dissolved oxygen and temperature probes fitted with SICRAM module can store factory and calibration data inside. The HD 98569 is a datalogger, it memorizes up to 200 single screens ( labels) and up to 9000 samples in continuous storage mode: pH or mV, conductivity or resistivity or TDS or salinity, concentration of dissolved oxygen and satura- tion index and temperature. The data can be transferred from the instrument connected to a PC via the multi-standard RS232C serial port and USB 2.0-1.1. The instruments equipped with HD22BT Bluetooth option can transfer the data without any connection to a PC fitted with USB/ Bluetooth converter HD USBKL1, or to the printer S’ print-BT with Bluetooth interface or to a PC with Bluetooth input. The serial connection RS232C can be used for direct printing of labels with a 24 column printer ( S’ print-BT) . The software DeltaLog11 ( vers. 2.0 and subsequent ones) allows instrument management and configuration, and data processing on PC. Technical characteristics of HD 98569 Measured values pH - mV- Ç - © - TDS - NaCl mg/ l O2 - % O2- ° C - ° F Instrument Dimensions ( Length x Width x Height) 250x100x50mm Weight 640g ( complete with batteries) Materials ABS, rubber Display Graphic, back lighted LCD, 56x38mm. 128x64 points Operating conditions Working temperature -5 … 50° C Storing temperature -25 … 65° C Working relative humidity 0 … 90% RH without condensate Protection degree IP66 Power Batteries 4 batteries 1.5V type AA Autonomy ( with probes connected) 25 hours with 1800mAh alkaline batteries Mains ( cod. SWD10) 12Vdc/ 1A ( positive at centre) Security of memorized data Unlimited Time Date and hour Schedule in real time Accuracy 1min/ month max. departure Continuous storage ( LOG key) Quantity 9000 samples of the three inputs Type organised in 1800 pages containing 5 samples each Storage interval 1s … 999s Storage on command ( MEM key) Quantity 200 samples of the three inputs Type organised in 200 pages containing 1 sample each Calibration storage pH and Dissolved Oxygen Last 8 pH and dissolved oxygen calibrations. The last 2 are saved in the SICRAM memory of the probe as well. Conductivity Last calibration is saved in the SICRAM memory of the probe. RS232C serial interface Type RS232C electrically isolated Baud rate Can be set from 1200 to 38400 baud Data bit 8 Parity None Stop bit 1 Flow control Xon/ Xoff Length of serial cable Max 15m USB interface Typ 1.1 - 2.0 electrically isolated Bluetooth interface Optional for PCs fitted with Bluetooth input or HD USB.KL1 Bluetooth / RS232 adapter. The interface can be installed in Delta Ohm only. EMC standard regulations Security EN61000-4-2, EN61010-1 level 3 Electrostatic discharge EN61000-4-2 level 3 Electric fast transients EN61000-4-4 level 3, EN61000-4-5 level 3 Voltage variations EN61000-4-11 Electromagnetic interference susceptibility IEC1000-4-3 Electromagnetic interference emission EN55020 class B Connections Enabled inputs for temperature probes with SICRAM module 8-pole male DIN45326 connector Input for pH/ temperature with SICRAM module 8-pole male DIN45326 connector Input for conductivity/ temperature with SICRAM module 8-pole male DIN45326 connector Input for dissolved oxygen/ temperature with SICRAM module 8-pole male DIN45326 connector RS232C / USB interface 8-pole MiniDin female connector Bluetooth Optional Mains adapter 2-pole( Ø 5.5mm- Ø 2.1mm) . Positive at centre ( e.g. SWD10) . Measurement of pH by instrument Measuring range -9.999… + 19.999pH Resolution 0.01 o 0.001pH selectable from menu Accuracy ± 0.001pH ± 1digit Input impedance > 1012© Calibration error @ 25° C | Offset| > 20mV Slope > 63mV/ pH or Slope 106.5% or Sensitivity < 85% Calibration points Up to 5 points from a list of 8 automatically detected buffers Temperature compensation -50...150° C Automatically detected standard solutions @ 25° C 1.679pH - 4.000pH - 4.010pH 6.860pH - 7.000pH - 7.648pH 9.180pH - 10.010pH Measurement of mV by instrument Measuring range -1999.9… + 1999.9mV Resolution 0.1mV Accuracy ± 0.1mV ± 1digit Drift after 1 year 0.5mV/ year Measurement of conductivity by instrument Resolution Measurement range ( K cell= 0.01) 0.000… 1.999¼ S/ cm 0.001¼ S/ cm Measurement range ( K cell= 0.1) 0.00… 19.99¼ S/ cm 0.01¼ S/ cm Measurement range ( K cell= 1) 0.0… 199.9¼ S/ cm 0.1¼ S/ cm 200… 1999¼ S/ cm 1¼ S/ cm 2.00… 19.99mS/ cm 0.01mS/ cm 20.0… 199.9mS/ cm 0.1mS/ cm Measurement range ( K cell= 10) 200… 1999mS/ cm 1mS/ cm Accuracy ( conductivity) instrument ± 0.5% ± 1digit Measurement of resistivity by instrument Resolution Measurement range ( K cell= 0.01) Up to 1G© Å cm Measurement range ( K cell= 0.1) Up to 100M© Å cm ( * ) Measurement range ( K cell= 1) 5.0… 199.9© Å cm 0.1© Å cm 200… 999© Å cm 1© Å cm 1.00k… 19.99k© Å cm 0.01k© Å cm 20.0k… 99.9k© Å cm 0.1k© Å cm 100k… 999k© Å cm 1k© Å cm 1… 10M© Å cm 1M© Å cm Measurement range ( K cell= 10) 0.5… 5.0© Å cm 0.1© Å cm Accuracy ( resistivity) instrument ± 0.5% ± 1digit Measurement of total dissolved solids Resolution ( with coefficient Ç / TDS= 0.5) Measurement range ( K cell= 0.01) 0.00… 1.999mg/ l 0.005mg/ l Measurement range ( K cell= 0.1) 0.00… 19.99mg/ l 0.05mg/ l Measurement range ( K cell= 1) 0.0… 199.9 mg/ l 0.5 mg/ l 200… 1999 mg/ l 1 mg/ l 2.00… 19.99 g/ l 0.01 g/ l 20.0… 199.9 g/ l 0.1 g/ l Measurement range ( K cell= 10) 100… 999 g/ l 1 g/ l Accuracy ( total dissolved solids) instrument ± 0.5% ± 1digit Measurement of salinity Resolution Measurement range 0.000… 1.999g/ l 1mg/ l 2.00… 19.99g/ l 10mg/ l 20.0… 199.9 g/ l 0.1 g/ l Accuracy ( salinity) instrument ± 0.5% ± 1digit Automatic/ manual temperature compensation 0...100° C with ± T = 0.00… 4.00% / ° C Reference temperature 0… 50° C ( Default values 20° C or 25° C) Conversion factor Ç / TDS 0.4… 0.8 Admitted cell constants K ( cm-1) 0.01… 20.00 Automatically detected standard solutions ( @ 25° C) 147¼ S/ cm 1413¼ S/ cm 12880¼ S/ cm 111800¼ S/ cm n Measurement of concentration of dissolved oxygen Measurement range 0.00… 90.00mg/ l Resolution 0.01mg/ l Accuracy instrument ± 0.03mg/ l ± 1digit ( 60...110% , 1013mbar, 20...25° C) Measurement of saturation index of dissolved oxygen Measurement range 0.0… 600.0% Resolution 0.1% Accuracy instrument ± 0.3% ± 1digit ( in the range 0.0… 199.9% ) ± 1% ± 1digit ( in the range 200.0… 600.0% ) Salinity setting Setting directly from menu or automatically by conductivity measurement Setting range 0.0… 70.0g/ l Resolution 0.1g/ l Temperature measurement with the sensor inside the O2 probe Measurement range 0.0… 50.0° C Resolution 0.1° C Accuracy instrument ± 0.1° C Drift after 1 year 0.1° C/ year Automatic temperature compensation 0… 50° C Measurement of temperature by instrument Pt100 Measurement range -50… + 150° C Resolution 0.1° C Accuracy instrument ± 0.1° C ± 1digit Drift after 1 year 0.1° C/ year
Tampilkan Lebih Banyak